The MR1 system
Autonomous microwave system for treating hazardous healthcare waste with EWC codes 18 01 01 and 18 01 03*

Principle of operation
The method is an alternative to the widespread incinerator and autoclave methods. It treats the waste in a microwave field, which ensures optimal heating from the inside out – a result of the high-frequency oscillation of the particles.
The unit is designed for thermal disinfection of infectious wet and/or dry waste, liquids and more. Treatment uses high-frequency microwave energy once water is added.
The process disinfects effectively even closed and hollow forms, thanks to even heating of both their surface and their interior. After treatment, the residue has the characteristics of safe municipal waste.
How it works
1. Collection
Waste is collected directly in the MR1 container, at the place where it is produced.
2. Loading
The container is placed in the chamber with no transfer or sorting.
3. Disinfection
Once water is added, microwave energy heats the waste evenly from the inside out. One cycle takes about 35 minutes.
4. Disposal
The residue has the characteristics of safe municipal waste, and the container is reused.




What the MR1 treats
The MR1 can treat:
- Used empty blood bags
- Drainage equipment
- Needles, syringes and other single-use instruments
- Single-use protective equipment and used dressings
- Haemodialysis consumables, culture media in Petri dishes
- Other
Advantages
- Meets all the goals in the “Human medicine waste” section of the NWMP (National Waste Management Plan)
- Collection, transport and treatment that are safe for staff, with no additional handling (transfer and sorting before disinfection)
- Waste is disinfected where it is generated – no risk is passed on to the public sector
- Waste is disinfected together with its collection containers – no chemical disinfectants are needed for the containers
- Lower overall cost of managing hazardous healthcare waste
- Capacity can be upgraded when needed
- Technological compatibility with the future construction of plants for processing and recycling non-hazardous waste
Lower costs
Operating costs are reduced through:
No external steam supply
Reusable container

No transport costs
Because disinfection takes place inside the hospital.
No additional chemical agents or labour for disinfecting the containers
Technical data
| Waste codes (EWC) | 18 01 01, 18 01 03* |
|---|---|
| Method | Microwave thermal disinfection (with added water) |
| Dimensions (H × W × D) | 1800 × 1200 × 1400 mm |
| Space required | 25–30 m² on the premises of the healthcare facility |
| Cycle duration | about 35 min |
| Capacity – one shift (8 h) | ~150 kg/day |
| Capacity – two shifts (8 h each) | ~6,500 kg/month |
| External steam / chemicals | not required |
| Emissions | no harmful vapours or smoke |
| Control | touch panel with an archive of alarms, graphs and data |
| Manufacturer | BMR Ltd., Bulgaria |

Automatic control
The unit is operated from a touch panel with an archive of alarms, graphs and data.
- Cycle and disinfection timer
- Temperature and load weight
- Graphs, data and counters
- Alarm archive

Certification
The MR1 autonomous microwave system is made by the Bulgarian company BMR Ltd. and meets all European safety requirements for operation.
Its microbiological efficacy is proven and certified by Test Report No. 8 of 21 April 2017, and by follow-up certification in 2025 from the National Centre of Infectious and Parasitic Diseases (NCIPD) under the Ministry of Health.
The company is certified to ISO 9001, ISO 14001 and ISO 45001.
NCIPD – Test Report No. 8 / 2017, certification 2025
ISO 9001
ISO 14001
ISO 45001